Product Description
Small incubator/family incubator/full automatic *****'s capacity is ***2pcs egg.
1. Open the box and check the incubator, check whether all of the accessories inside of the packing box are well-equipped.
2. Before use, remove the top cover on the incubator, there are movable egg tray bracket and egg tray mesh inside the base. In order to prevent damage during the transportation, the base, movable egg tray bracket and egg tray mesh are tied up during package, please disassemble it before use.
3. Take movable egg tray bracket and egg tray mesh out of the base. Wash and clean the base, feed water to tank A and B inside of base, then put the movable egg tray bracket into the base, check whether the motor power supply of movable bracket is connected well or not, it shall be connected with special connector of top cover.
4. After covering the top cover, rightly connect the power line and switch on the power supply, if data on the control panel displays in normal condition, the heating indicator will be on after 2 minutes and the incubator will begin to heat up.
5. Adjust the temperature at *8â?? by adjusting knob. Check all of the data after *0 minutes. Countdown displays minute change and number of days (change once for every *4h), the incubation temperature requires at *7.*-incubator.........
I.Cautions:
Unpack the box and check the incubator, check whether all of the
accessories inside of the packing box are
well-equipped. See packing list for details.
Note: when ambient temperature is less than *5℃, measure shall be
taken for heat preservation, it’s good for
temperature uniformity when the device is enclosed with clothes or
other warms, and it also helps energy-saving
and reduces heat dissipation. Use thermometer to correct
temperature display before use, CA parameter can
be adjusted.
The incubator can be put into running after *-hour trial run.
II. Operating Steps:
1. Push the mesh with rail (big mesh) (fig. 1) into the
incubator.
2. Put the movable egg tray (fig.2) on the mesh with rail, please
do put it within the rail.
3. Put the egg tray grille (fig.3) into movable egg tray according
to size of egg for incubation.
4.Put the hatching egg into movable egg tray (fig. 5) for
incubation, pay attention that after each egg is put into the
grille, there should be 5mm clearance at least for convenient
turning of hatching egg, inject **0ml water into the
base after the hatching egg is put, check once for every two days
so that the incubator is not short of water.
Every water injection shall not be more than **0ml, take down the
date of placing hatching egg so as to well
control the hatching time. It’s best to place the incubator on
*****0CM table for convenient insertion of link
rod.
5. When closing the cover (fig. 7), the link rod must insert the
shifting slot of movable egg tray, so that the egg
tray can shift normally.
6. Switch on the power supply after closing the cover, and set the
temperature according to Push-Button
Instruction and Incubation Technology.
If the user has no time to care about the temperature, the
temperature can be set at *8℃from the first day of
incubation to first day of hatching, and it can be set as *7.5
**7.8℃ since the following day of hatching.
7. It moves to hatching tray 3 days earlier than incubation period
for other poultry
8. It usually takes **4 days less than the number of incubation
days for egg tray replacement, replace the egg tray
once one or two hatching eggs are seen hatched, take all of the
hatching eggs off from the incubator firstly, then
take the movable egg tray and mesh with rail out, check the water
level, then put the hatching mesh (fig. *0) and
egg tray in and put the hatching egg on the egg tray, shown as fig.
*1.
9. After closing the cover and switching on the power supply, the
hatching situation can be observed.
III. Important for Safety
1. Only the power supply marked on the in cuba tor can be used,
******0v;
2.Don’t put any goods on the wire, the power line of incubator
shall be placed where it won’t be stepped on or
make people trip and fall;
3. Make sure that the socket and extension line in use have no
overload, otherwise, it may cause fire or electric
shock;
4. If the incubator is smoking, or sending abnormal smell or
unusual noise, please cut off the power supply and
pull down the power line to stop the fault, after that, contact the
agency or maintenance center;
5. Please don’t touch the power line with wet hand, or it may cause
electric shock;
6. This incubator can’t be exposed to rain and sunshine;
7. Make sure that the power supply is switched off before cleaning
the incubator;
8. The incubator shall be placed in room where is ventilated
without vibratory equipment, it can’t be placed in
room with fast
air movement or room with harmful and noxious chemicals and other
pollutants.
9. Don’t block the air-bleed hole when the incubator is in work
condition.
IV.Push- Instruction:
1. SET:
A: Push SET once to enter temperature control set, push <+>
or <-> to adjust parameter, push<+>or <-> for
3s
to enter fast adjustment mode, push SET again to exit from setting
state.
B: Push SET for 3s to enter system menu set, push <+> or
<-> to select menu in need of adjustment, then push
SET again to enter relative parameter setting state, push <+>
or <-> to adjust parameter in need of modification,
push RST to exit after adjustment, or the system will exits after
5s delay.
2.<+>:Up
3.<->: Down
Operation Instruction:
Indicating lamp state instruction:
WORK lamp on the left side of display screen is made as work
indicating lamp, LED normally on means it’s in
heating state.
SET lamp on the left side of display screen is used for indicating
lamp set, LED normally on means it’s in setting
state.
Function instruction:
◆HU,HD:
Parameter HU and HD is set by factory, the user unless the
professional is not allowed to adjust it.
◆Temperature correction set:
When measuring temperature deviates from reference temperature,
temperature correction function shall
be used to make the measuring value in accordance with reference
temperature, temperature after correction
shall be the sum of temperature before correction and correction
value (correction value can be positive number,
negative number or zero).
◆Temperature correction set:
Push “SET” for 3s to enter menu display, push <+> or
<-> until code “CA” appears on screen, then push “SET”
to display temperature correction setting value, push <+> or
<-> again to adjust parameter.
◆Upper and lower limit function:
HS and LS set limits setting range of temperature control, e.g., if
HS is set as *9.5 and LS is set as *0, then the
temperature can only be set from *0 to *9.5, so the display value
still keeps as *0 after pushing “-” if it displays
*0; the display value still keeps as *9.5 after pushing “+” if it
displays *9.5. If setting value is beyond the setting
range, then HS and LS must be changed at first.
◆ Upper and lower limit set:
Push “SET” for 3s to enter menu display, push <+> or
<-> until code “HS” or “LS” appears on screen, push
“SET” to display upper or lower limit setting value, then push
<+> or <-> to adjust the parameter. HS means
upper limit and LS means lower limit.
Code Description Setting range Factory set Unit
HU Heating power parameter ***0 -
HD Heat preservation power parameter ***0 -
LS Lower limit set *9.9~HS - ℃
HS Upper limit set LS~*9.9 - ℃
CA Temperature correction *5~*5 *- ℃
AH Factory set, not adjustable ***5 - ℃
AL Factory set, not adjustable ***5 - ℃
V. Incubation Technology
1. Incubation temperature control
Different poultry requires different temperatures: incubation
period of chicken is *1 days, it’s *8.2℃ from
1st~6th day, *8℃ from 7th~*4th day, *7.8℃ on *5th day, and
*7.2~*7.5℃ from *6th~*1st day.
2.Humidity control: It requires different relative humidity in
different period of incubation. The relative humidity
shall keep within *5%~*0% at the earlier stage of incubation to
ensure even heating for embryo, which is good
for formation of allantoic fluid and amniotic fluid, the relative
humidity shall keep within *0%~*5% at the middle
stage of incubation, which is good for evaporation of water, the
relative humidity at the last stage of incubation
shall be increased to *5%~*5%, as high relative humidity is good
for poult to hatch, when above *0% of poult
hatches, the relative humidity shall keep at *5%~*5%.
3. Cleaning and sterilization before incubation: wash and clean the
incubator, then suffumigate it with potassium
permanganate and formalin.
4. Incubation equipment inspection before incubation: check all of
the parts completely and observe whether the
fan rotation device works normally and whether all of the
components are in good condition, then adjust the
temperature and feed water to the tank. Make a ****4 hours’ trial
again when the incubator reaches
temperature and humidity requirement, if the incubator works
normally, it can be put into running.
5.Choose and store fresh egg within 5 days (7 days at most) as
hatching egg, as for the egg stored for more
than 5 days, 4% less the incubation rate and *0 minutes prolonged
incubation period for one more day storage.
The proper temperature for hatching egg storage is *2℃~*6℃.The
smaller side shall be put upside during
hatching egg storage.
6. Notes for off-tray period: The process to remove from egg tray
to hatching tray is called off-tray, the chick
embryo usually removes off the tray at an age of ****9 days. It
shall be placed gently during off-tray, it’s best to
lay to single layer. It also removes to hatching tray 3 days
earlier than incubation period for other
Country: |
China |
Model No: |
JN12
|
FOB Price: |
( Negotiable ) (Negotiable)
Get Latest Price
|
Place of Origin: |
china |
Price for Minimum Order: |
- |
Minimum Order Quantity: |
30 Set |
Packaging Detail: |
box/carton |
Delivery Time: |
within 20 days after received payment |
Supplying Ability: |
100000 Set per Year |
Payment Type: |
T/T, Western Union, Money Gram |
Product Group : |
- |